TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 264 of 1396

TM 9-2320-366-20-3 KNOWN INFO TEST OPTIONS YES REASON FOR QUESTION Pressure Test or STE/ICE-R Test #51 NO Replace suspension compression tee fitting (para 19-12). If 2,500-4,000 psi (17,238- 27,580 kPa) is present, suspension compression tee fitting is faulty. 4. Other hydraulic manifold functions OK. Hydraulic hoses free from leaks. Hydraulic hoses 508 and 510 OK. Hydraulic hose 513 OK. Suspension release tee fitting OK. Suspension cylinders OK. Hydraulic hoses 509 and 511 OK. POSSIBLE PROBLEMS Faulty suspension compression tee fitting. Faulty air/hydraulic manifold. Faulty hydraulic hose 512. Go to step 5 of this fault. 2-2230.6 Change 1 Is 2,500-4,000 psi (17,238-27,580 kPa) present at suspension compression tee fitting input port? u2. SUSPENSION DOES NOT COMPRESS AND/OR RETURN TO NORMAL (CONT)