PRESSURE TEST (1) Position drain pan under air/hydraulic manifold. (2) Disconnect hydraulic hose 515 from port P1. (3) Connect STE/ICE-R between hydraulic hose 515 and port P1. (4) Start engine (TM 9-2320-366-10-1). (5) Position SUSPENSION knob to LOWER (TM 9-2320-366-10-1). (6) Position FUNCTION SELECT knob to SUSPENSION (TM 9-2320-366-10-1). (7) Push and hold PUMP plunger button (TM 9-2320-366-10-1) and perform STE/ICE-R Test #51. (8) If 2,500-4,000 psi (17,238-27,580 kPa) is not present, go to step 5 of this fault. (9) If 2,500-4,000 psi (17,238-27,580 kPa) is present, replace air/hydraulic manifold (para 19-4). (10) Disconnect STE/ICE-R from hydraulic hose 515 and port P1. (11) Connect hydraulic hose 515 to port P1. Change 1 2-2225 TM 9-2320-366-20-3