TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 220 of 1396

TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 2-2210 2-2210 2-2210 2-2210 2-2210 TEST OPTIONS KNOWN INFO 3. YES NO Winch Control Valve Fault Check REASON FOR QUESTION Replace winch control valve (para 17-25). Perform Electrical System Troubleshooting (e88. Self- Recovery Winch Does Reel In or Pay Out). Hydraulic oil level OK. Hydraulic lines and fittings OK. Hydraulic pump OK. 15K self-recovery winch OK. POSSIBLE PROBLEMS Faulty winch control valve. Faulty electrical supply/ control valve solenoid. Is pressure totally absent at V1 and/or V2 on 15K self-recovery winch? A faulty electrical system or winch control valve will cause pressure to be absent at both ports on 15K self-recovery winch. s1. 15K SELF-RECOVERY WINCH DOES NOT WORK (CONT) s1. 15K SELF-RECOVERY WINCH DOES NOT WORK (CONT) s1. 15K SELF-RECOVERY WINCH DOES NOT WORK (CONT) s1. 15K SELF-RECOVERY WINCH DOES NOT WORK (CONT) s1. 15K SELF-RECOVERY WINCH DOES NOT WORK (CONT)