TM 9-2320-366-20-3 b. Installation. (1) Position terminal lug TL12 (1) on starter solenoid (2) with nut (3). (2) Tighten nut (3) to 15-20 lb-ft (20-27 N·m). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (3) Apply adhesive to terminal lug TL12 (1) on starter solenoid (2). NOTE Both clamps are installed the same way. One shown. (4) Install two clamps (4) on battery to starter cable assembly (5). NOTE Steps (5) through (7) require the aid of an assistant. (5) Position battery to starter cable assembly (5) on frame rail (6) with clamp (4), screw (7) and self-locking nut (8). (6) Perform Step (5) on remaining clamp. NOTE Install plastic cable ties as required. (7) Tighten two self-locking nuts (8) to 97-124 lb-in. (11-14 N·m). Change 1 7-353