TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 1101 of 1396
TM 9-2320-366-20-3 b. Installation. NOTE Install plastic cable ties as required. (1) Position battery to 100 amp reverse polarity relay 12 vdc cable (1) on vehicle. (2) Position terminal lugs TL47 (2) and TL61 (3) on 100 amp reverse polarity relay 12 VDC BAT terminal (4) with lockwasher (5) and nut (6). (3) Tighten nut (6) to 120-144 lb-in. (14-16 N·m). (4) Position terminal cover (7) on terminal lugs TL47 (2) and TL61 (3). c. Follow-On Maintenance. (1) Raise spare tire (TM 9-2320-366-10-2). (2) Connect batteries (para 7-57). (3) Start engine (TM 9-2320-366-10-1). (4) Check VOLTS gage for charge indication (TM 9-2320- 366-10-1). (5) Shut down engine (TM 9-2320-366-10-1). End of Task. 7-345