TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 1100 of 1396

TM 9-2320-366-20-3 7-74. BATTERY TO 100 AMP REVERSE POLARITY RELAY 12 VDC CABLE REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions Spare tire lowered (TM 9-2320-366-10-2). Cab raised (TM 9-2320-366-10-1). Batteries disconnected (para 7-57). Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C) Socket Set, Socket Wrench (Item 34, Appendix C) Materials/Parts Ties, Cable, Plastic (Item 63, Appendix C) Lockwasher (Item 96, Appendix G) a. Removal. (1) Lift terminal cover (1) on terminal lugs TL61 (2) and TL47 (3). NOTE Remove plastic cable ties as required. (2) Remove nut (4), lockwasher (5), and terminal lugs TL61 (2) and TL47 (3) from 100 amp reverse polarity relay 12 VDC BAT terminal (6). Discard lockwasher. NOTE Note routing of 100 amp reverse polarity relay 12 vdc cable prior to removal. (3) Remove battery to 100 amp reverse polarity relay 12 vdc cable (7) from vehicle. 7-344