TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 1098 of 1396
TM 9-2320-366-20-3 7-73. 100 AMP ALTERNATOR TO REVERSE POLARITY RELAY 24 VDC CABLE REPLACEMENT (CONT) b. Installation. (1) Install three clamps (1) on 100 amp alternator to reverse polarity relay 24 vdc cable (2). NOTE Install plastic cable ties as required. (2) Position 100 amp alternator to reverse polarity relay 24 vdc cable (2) on engine (3) with three clamps (1), washers (4), and screws (5). (3) Tighten three screws (5) to 22-27 lb-ft (31-37 N·m). (4) Install 100 amp alternator to reverse polarity relay 24 vdc cable (2) in dust boot (6). CAUTION Insulation washer must be installed with flat side up. Failure to comply may result in damage to equipment. (5) Position terminal lugs TL6 (7) and TL2 (8) on alternator (9) with insulation washer (10), washer (11) and self-locking nut (12). (6) Tighten self-locking nut (12) to 40 lb-in. (5 N·m). (7) Position dust boot (6) on terminal lugs TL2 (8) and TL6 (7). 7-342