TM 9-2320-366-20-3 7-73. 100 AMP ALTERNATOR TO REVERSE POLARITY RELAY 24 VDC CABLE REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions Spare tire lowered (TM 9-2320-366-10-2). Cab raised (TM 9-2320-366-10-1). Batteries disconnected (para 7-57). Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Wrench, Torque, 0-175 lb-ft (Item 58, Appendix C) Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C) Socket Set, Socket Wrench (Item 34, Appendix C) Materials/Parts Dispenser, Pressure Sensitive Adhesive Tape (Item 20, Appendix D) Ties, Cable, Plastic (Item 69, Appendix D) Lockwasher (Item 96, Appendix G) Nut, Self-Locking (Item 143, Appendix G) a. Removal. (1) Loosen clamp (1) on turbocharger intake hose (2). (2) Remove turbocharger intake hose (2) from intake air cleaner boot (3). (3) Lift terminal cover (4) on terminal lugs TL1 (5), TL36 (6), and TL37 (7). NOTE Remove plastic cable ties as required. (4) Remove nut (8), lockwasher (9), and terminal lugs TL1 (5), TL36 (6), and TL37 (7) from reverse polarity relay 24 VDC LOAD terminal (10). Discard lockwasher. 7-340