TM 9-2320-366-20-3 7-72. 100 AMP ALTERNATOR TO REVERSE POLARITY RELAY 12 VDC CABLE REPLACEMENT (CONT) (4) Install dust boot (6) on 100 amp alternator to reverse polarity relay 12 vdc cable (2). CAUTION Insulation washer must be installed with flat side up. Failure to comply may result in damage to equipment. (5) Position terminal lug TL60 (7) on alternator (8) with insulator washer (9), washer (10) and self-locking nut (11). (6) Tighten self-locking nut (11) to 40 lb-in. (5 N m). (7) Position dust boot (6) on terminal lug TL60 (7). (8) Position terminal lugs TL61 (12) and TL47 (13) on reverse polarity relay 12 VDC LOAD terminal (14) with lockwasher (15) and nut (16). (9) Tighten nut (16) to 120-144 lb-in. (14-16 N·m). (10) Position terminal cover (17) on terminal lugs TL47 (13) and TL61 (12). (11) Position turbocharger intake hose (18) on intake air cleaner boot (19) with clamp (20). (12) Tighten clamp (20) to 36-48 lb-in. (4-5 N·m). 7-338