TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 1092 of 1396

TM 9-2320-366-20-3 7-72. 100 AMP ALTERNATOR TO REVERSE POLARITY RELAY 12 VDC CABLE REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions Spare tire lowered (TM 9-2320-366-10-2). Cab raised (TM 9-2320-366-10-1). Batteries disconnected (para 7-57). Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Wrench, Torque, 0-175 lb-ft (Item 58, Appendix C) Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C) Socket Set, Socket Wrench (Item 34, Appendix C) Materials/Parts Dispenser, Pressure Sensitive Adhesive Tape (Item 20, Appendix D) Ties, Cable, Plastic (Item 69, Appendix D) Lockwasher (Item 96, Appendix G) Nut, Self-Locking (Item 144.1, Appendix G) a. Removal. (1) Loosen clamp (1) on turbocharger intake hose (2). (2) Remove turbocharger intake hose (2) from intake air cleaner boot (3). (3) Lift terminal cover (4) on terminal lugs TL47 (5) and TL61 (6). NOTE Remove plastic cable ties as required. (4) Remove nut (7), lockwasher (8), and terminal lugs TL47 (5) and TL61 (6) from reverse polarity relay 12 VDC LOAD terminal (9). Discard lockwasher. 7-336 Change 1