TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 1045 of 1396

TM 9-2320-366-20-3 (4) Remove nut (9) and terminal lug TL99 (10) from battery 12 VDC cable (11). b. Connecting. WARNING Negative battery terminals must be connected last. Failure to comply may result in serious injury or death to personnel. (1) Install terminal lug TL99 (1) on battery 12 VDC cable (2) with nut (3). (2) Install washer (4) battery tester terminal lug (5), and terminal lugs TL48 (6) and TL50A (7) on battery 24 VDC ground cable (8). (3) Deleted. (4) Install lockwasher (10) and nut (11) on battery 24 VDC ground cable (8). (5) Apply grease to all battery terminals. Change 1 7-289