TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 977 of 1632
AUXILIARY OIL COOLER FAN TEST  (1) Raise cab (TM 9-2320-366-10-1).  (2) Disconnect connector clamp from water  temperature sensor.  (3) Disconnect connector P36 from water  temperature sensor (S56) to de-energize  relay K15 and provide power to auxiliary oil  cooler fan.  (4) Position master power switch to on  (TM 9-2320-366-10-1).  (5) Check if auxiliary oil cooler fan comes on.  (6) If fan does not come on, perform  Electrical System Troubleshooting (e148.  Transmission Auxiliary Oil Cooler Fan Does  Not Operate (All Models Except  M1088/M1089) or e149. M1088/M1089  Transmission Auxiliary Oil Cooler Fan Does  Not Operate).  (7) Position master power switch to off  (TM 9-2320-366-10-1).  (8) Connect connector P36 to water  temperature sensor (S56).  (9) Connect connector clamp on water  temperature sensor.  (10) Lower cab (TM 9-2320-366-10-1).  Change 1 2-1734.1  TM 9-2320-366-20-2