TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 95 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-981 2-981 2-981 2-981 2-981 VOLTAGE TEST Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuit and cause severe burns or electrical shock. WARNING (1) Remove auxiliary panel and tilt back. Do not disconnect connectors (para 7-8). (2) Disconnect connector P902 from winch power switch. (3) Set multimeter to volts dc. (4) Connect positive (+) probe of multimeter to connector P902 terminal 6. (5) Connect negative (-) probe of multimeter to ground. (6) Position master power switch to on (TM 9-2320-366-10-1). (7) Position PTO switch to on (TM 9-2320-366-10-1) and note reading on multimeter. (8) If 24 vdc is not present, repair wire 1904 (para 2-45) or replace auxiliary panel cable assembly (para 7-58). (9) Position PTO switch to off (TM 9-2320-366-10-1). (10) Position master power switch to off (TM 9-2320-366-10-1).