TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 917 of 1632

CAUTION Use care when testing electrical connectors not to bend connector pins or damage connector sockets with multimeter probes. Failure to comply may result in damage to equipment. NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. CONTINUITY TEST (10) Connect connector J115 to WTEC II TEPSS connector. (11) Install kick panel (para 16-3). (12) Install instrument panel assembly (para 7-15). (13) Clear diagnostic codes (para 8-4). Change 1 2-1706.15 (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector J116 socket A1. (3) Connect negative (-) probe of multimeter to connector J115 socket 9 and note reading on multimeter. (4) Connect negative probe (-) of multimeter to all other sockets in connector J115 and note reading on multimeter. (5) Connect negative probe (-) of multimeter to ground and note reading on multimeter. (6) If continuity is not present in step (3), or continuity is present in step (4) or step (5), replace WTEC II cab transmission harness (para 7-137). (7) If continuity is present in step (3) and continuity is not present in step (4) or (5), replace WTEC II TEPSS (para 8-2). (8) Connect connector J116 to VIM connector. (9) Tighten screw in connector J116. TM 9-2320-366-20-2