TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 911 of 1632

TM 9-2320-366-20-2 CAUTION Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. CONTINUITY TEST (1) Remove seven screws and washers from WTEC II VIM cover. (2) Remove screw, washer, WTEC II VIM cover, and nut from WTEC II VIM. (3) Remove 10 AMP MAIN POWER fuse from WTEC II VIM. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to one terminal on 10 AMP MAIN POWER fuse. (6) Connect negative (-) probe of multimeter to other terminal on 10 AMP MAIN POWER fuse and note reading on multimeter. (7) If continuity is not present, replace 10 AMP MAIN POWER fuse (para 8-6). (8) Position WTEC II VIM cover on WTEC II VIM with washer, screw, and nut. (9) Install seven washers, and screws in WTEC II VIM cover. Change 1 2-1706.9