TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 89 of 1632
TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-975 2-975 2-975 2-975 2-975 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P110-R. (3) Connect negative (-) probe of multimeter to connector P112-D and note reading on multimeter. (4) If continuity is not present, replace CTIS cable assembly (para 7-60). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P110-F. (3) Connect negative (-) probe of multimeter to connector P112-B and note reading on multimeter. (4) If continuity is not present, replace CTIS cable assembly (para 7-60). (5) Connect connector P112 to manifold valve assembly.