TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 855 of 1632
RESISTANCE TEST  (9) Verify that difference between highest  (high idle) reading and lowest (low idle)  reading is between 4,000 and 6,000  ohms.  (10) Verify that highest (high idle) reading does  not exceed 15,000 ohms.  (11) If resistance readings are not within limits,  replace TPS cable assembly (para 4-16).  (1) Disconnect connector P73 from TPS  connector.  (2) Set multimeter to ohms.  (3) Connect positive (+) probe of multimeter  to TPS terminal A.  (4) Connect negative (-) probe of multimeter to  TPS terminal C and verify multimeter reads  between 9,000-15,000 ohms across  terminals A and C.  (5) Disconnect negative (-) probe of  multimeter from terminal C.  (6) Connect negative (-) probe of multimeter  to TPS terminal B and note record on  multimeter.  (7) Move governor linkage to high idle stop  and record reading on multimeter.  (8) Return governor linkage to low idle stop.  TM 9-2320-366-20-2  Change 1 2-1661  (1) Raise cab (TM 9-2320-366-10-1).  (2) Verify distance between hitch pin clip on  end of sensor rod and center of cable  groove in ferrule is 4 in. (10 cm).  (3) If distance is not 4 in. (10 cm), adjust  bracket assembly to obtain correct  measurement.  LINKAGE TEST