TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 833 of 1632

RESISTANCE TEST (1) Set multimeter to ohms. (2) Connect positive (+) prove of multimeter to connector P119h. (3) Connect negative (-) probe of multimeter to connector P119j and note reading on multimeter. (4) If resistance is high (20,000 ohms or higher), replace WTEC II TEPSS (para 8-2). (5) If resistance is low (less than 20,000 ohms), notify DS Maintenance. (6) Connect connector J115 to WTEC II TEPSS. (7) Install instrument panel assembly (para 7-15). (8) Connect connector P119 to connector J119. (9) Position front grille on cab with washer and screw. (10) Position two washers and screws in front grille. (11) Tighten screw to 48-60 lb-in. (5-7 N·m). (12) Tighten two screws to 24 lb-in. (3 N·m). (13) Clear diagnostic codes (para 8-4). Change 1 2-1639 TM 9-2320-366-20-2