TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-969 2-969 2-969 2-969 2-969 CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P110-J. (3) Connect negative (-) probe of multimeter to connector P113-A and note reading on multimeter. (4) If continuity is not present, replace CTIS cable assembly (para 7-60). (5) If continuity is present, replace manifold valve assembly (para 12-7). (6) Connect connector P113 to manifold valve assembly. (7) Install kick panel (para 16-3). (8) Connect connector P110 to CTIS ECU.