CONTINUITY TEST  Change 1 2-1631  TM 9-2320-366-20-2  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  connector J119. Refer to Table 2-24. Main  Code 43 Sub Code 21 and 26 Low Side  Test Points.  (3) Connect negative (-) probe of multimeter to  connector J114 and note reading on  multimeter. Refer to Table 2-24. Main Code  43 Sub Code 21 and 26 Low Side Test  Points.  (4) Connect negative (-) probe of multimeter to  all other sockets in connector J114, one at a  time, and note reading on multimeter.  (5) Connect negative (-) probe of multimeter to  all sockets in connector J115, one at a time,  and note reading on multimeter.  (6) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (7) If continuity is not present in step 3, or  continuity is present in step 4, 5, or 6,  replace WTEC II cab transmission harness  (para 7-137).  Table 2-24. Main Code 43 Sub Code 21 and 26  Low Side Test Points  Sub  Code  Connector  J114  Connector  J119  21  26  10  1  H  A