TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 791 of 1632
CAUTION  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  NOTE  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  RESISTANCE TEST  TM 9-2320-366-20-2  Change 1 2-1599  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter  to connector P119 pin p.  (3) Connect negative (-) probe of multimeter to  connector P119 pin r and note reading on  multimeter.  NOTE  A good turbine speed sensor  will return a reading of 200-400  ohms resistance as follows:  a. 200 ohms at -40°F (-40°C).  b. 300 ohms at 68°F (20°C).  c. 400 ohms at 230°F (110°C).  (4) Connect negative (-) probe of multimeter to  all other pins in connector P119 and note  reading on multimeter.  (5) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (6) If 200-400 ohms resistance is not present  in step 4, or continuity is present in step 5  or step 6, notify DS Maintenance.  (7) If 200-400 ohms resistance is present in  step 3, and continuity is not present in  step 5 or step 6, replace WTEC II TEPSS  (para 8-2).  (8) Connect connector J115 to WTEC II  TEPSS.  (9) Install instrument panel assembly (para  7-15).  (10) Connect connector P119 to connector  J119.  (11) Position front grille on cab with washer  and screw.  (12) Position two washers and screws in front  grille.  (13) Tighten screw to 48-60 lb-in. (5-7 N·m).  (14) Tighten two screws to 24 lb-in. (3 N·m).  (15) Clear diagnostic codes (para 8-4).