TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 785 of 1632
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  CONTINUITY TEST  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  NOTE  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  CAUTION  (11) Position front grille on cab with washer  and screw.  (12) Position two washers and screws in front  grille.  (13) Tighten screw to 48-60 lb-in. (5-7 N·m).  (14) Tighten two screws to 24 lb-in. (3 N·m).  (15) Clear diagnostic codes (para 8-4).  TM 9-2320-366-20-2  (1) Set multimeter to ohms position.  (2) Connect positive (+) probe of multimeter  to connector socket J115-16.  (3) Connect negative (-) probe of multimeter to  connector socket J119s and note reading  on multimeter.  (4) Connect negative (-) probe of multimeter to  all other sockets in connector J119 and  note reading on multimeter.  (5) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (6) If continuity is not present in step 3, or  continuity is present in step 4 or step 5,  replace WTEC II cab transmission harness  (para 7-137).  (7) If continuity is present in step 3 and no  shorts circuits are found, replace WTEC II  TEPSS (para 8-2).  (8) Connect connector J115 to WTEC II  TEPSS.  (9) Install instrument panel assembly (para  7-15).  (10) Connect connector P119 to connector  J119.  Change 1 2-1593