TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 783 of 1632

CONTINUITY TEST CAUTION NOTE Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. (1) Remove instrument panel assembly for access (para 7-15). (2) Disconnect connector J115 (top connector) from WTEC II TEPSS. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to connector socket J115-7. (5) Connect negative (-) probe of multimeter to connector socket J119m and note reading on multimeter. (6) Connect negative (-) probe of multimeter to all other sockets in connector J119 and note reading on multimeter. (7) Connect negative (-) probe of multimeter to ground to and note reading on multimeter. (8) If continuity is not present in step 5, or continuity is present in step 6 or step 7, replace WTEC II cab transmission harness (para 7-137). TM 9-2320-366-20-2 Change 1 2-1591