TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2  2-963 2-963 2-963 2-963 2-963  CONTINUITY TEST  CONTINUITY TEST  (1) Remove kick panel (para 16-3).  (2) Disconnect connector P112 from manifold  valve assembly.  (3) Set multimeter to ohms.  (4) Connect positive (+) probe of multimeter to  connector P110-B.  (5) Connect negative (-) probe of multimeter to  connector P112-F and note reading on  multimeter.  (6) If continuity is not present, replace CTIS cable  assembly (para 7-60).  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  connector P110-F.  (3) Connect negative (-) probe of multimeter to  connector P112-A and note reading on  multimeter.  (4) If continuity is not present, replace CTIS cable  assembly (para 7-60).