TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 767 of 1632
TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1575 2-1575 2-1575 2-1575 2-1575 VOLTAGE TEST (1) Remove personnel heater to gain access (para 18-9). (2) Disconnect connector P913 from connector J913. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to connector J913-1. (5) Connect negative (-) probe of multimeter to PDP, relay K12 socket 86 and note reading on multimeter. (6) If continuity is not present, repair wire 1673 (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (7) If continuity is present, repair wire 1673 (para 2-45) or replace auxiliary panel cable assembly (para 7-58). (8) Connect connector P913 to connector J913. (9) Install relay K12 in PDP. (10) Install personnel heater (para 18-9). (11) Connect connector P906 to blackout override switch. (12) Position auxiliary panel on auxiliary panel housing with six screws. (13) Tighten six screws to 24 lb-in. (3 N·m).