TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 765 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1573 2-1573 2-1573 2-1573 2-1573 CONTINUITY TEST CONTINUITY TEST (1) Remove PDP cover (para 16-2). (2) Remove relay K12 from PDP. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to relay K12 socket 85. (5) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (6) If continuity is not present, repair wire 3067 (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to relay K12 pin 85. (3) Connect negative (-) probe of multimeter to relay K12 pin 86 and note reading on multimeter. (4) If continuity is not present, replace relay K12 (para 7-9).