TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 763 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1571 2-1571 2-1571 2-1571 2-1571 VOLTAGE TEST Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuit and cause severe burns or electrical shock. WARNING (6) Position master power switch to on (TM 9-2320-366-10-1) and note reading on multimeter. (7) If 12 vdc is not present, repair wire 1674 (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (8) If 12 vdc is present, repair wire 1674 (para 2-45) or replace auxiliary panel cable assembly (para 7-58). (9) Position master power switch to off (TM 9-2320-366-10-1). (10) Connect connector P913 to connector J913. (11) Install personnel heater (para 18-9). (12) Connect connector P906 to blackout override switch. (13) Position auxiliary panel on auxiliary panel housing with six screws. (14) Tighten six screws to 24 lb-in. (3 N·m). (1) Remove personnel heater to gain access (para 18-9). (2) Disconnect connector P913 from connector J913. (3) Set multimeter to volts dc. (4) Connect positive (+) probe of multimeter to connector J913-2. (5) Connect negative (-) probe of multimeter to ground.