TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1567 2-1567 2-1567 2-1567 2-1567 VOLTAGE TEST Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuit and cause severe burns or electrical shock. WARNING (1) Remove six screws from auxiliary panel. (2) Lift auxiliary panel from auxiliary panel housing outward to gain access. (3) Disconnect connector P906 from blackout override switch. (4) Set multimeter to volts dc. (5) Connect positive (+) probe of multimeter to connector P906-5. (6) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (7) If 12 vdc is not present, go to step 3 of this fault.