TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 758 of 1632
TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1566 2-1566 2-1566 2-1566 2-1566 1. START YES NO KNOWN INFO WARNING Read WARNING on following page. Is 12 vdc present at connector P906-5? This question eliminates possible problems and determines where troubleshooting continues. TEST OPTIONS Voltage Test or STE/ICE-R #89 REASON FOR QUESTION Circuit breaker OK. Worklights normal mode OK. POSSIBLE PROBLEMS Faulty blackout override switch. Faulty dashboard cable assembly. Faulty auxiliary panel cable assembly. Faulty relay K12. INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-366-10-1). Personnel Required (2) References TM 9-4910-571-12&P e151. M1088/M1089 WORKLIGHTS DO NOT ILLUMINATE IN BLACKOUT MODE WITH BLACKOUT OVERRIDE SWITCH ON Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) STE/ICE-R (Item 41, Appendix C) Multimeter, Digital (Item 22, Appendix C) Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C) Materials/Parts Wire, Elect, 50 ft (Item 71, Appendix D) Go to step 3 of this fault.