TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1565 2-1565 2-1565 2-1565 2-1565 CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P134-A or connector P134A-1. (4) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (5) If continuity is not present, repair wire 3061 (fixed worklight) or wire 3062 (hand-held worklight) (para 2-45) or replace rear lights cable assembly (para 7-104). (6) If continuity is present, replace RH tractor or wrecker worklight (para 7-42). (7) Connect worklight to connector P134 or P134A on RH tractor or wrecker.