TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 747 of 1632

TM 9-2320-366-20-2 VOLTAGE TEST (1) Set multimeter to ohms. (2) Remove diode D2B from PDP. (3) Connect positive (+) probe of multimeter to PDP, where relay K9 terminal 87 was removed. (4) Connect negative (-) probe of multimeter to PDP, where diode D2B terminal 4 was removed and note reading on multimeter. (5) If continuity is not present, repair wire 1565 from relay K9 terminal 87 to diode D2B terminal 4 (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (6) If continuity is present, replace relay K9 (para 7-9). (7) Install relay K9 in PDP. (8) Install diode D2B in PDP. (9) Install PDP cover (para 16-2). (10) Connect connector P905 to worklights switch. (11) Position auxiliary panel on auxiliary panel housing with six screws. (12) Tighten six screws to 24 lb-in. (3 N·m). Change 1 2-1555