TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 733 of 1632
TM 9-2320-366-20-2 (1) Remove six screws from auxiliary panel. (2) Lift auxiliary panel from auxiliary panel housing to gain access. (3) Disconnect connector P905 from worklights switch. (4) Set multimeter to volts DC. (5) Connect positive (+) probe of multimeter to connector P905 socket 5. (6) Connect negative (-) probe of multimeter to ground. (7) Position main light switch to STOP LIGHT (TM 9-2320-366-10-1) and note reading on multimeter. (8) If 12 VDC is not present, go to step 7 of this fault. (9) Position main light switch to OFF (TM 9-2320-366-10-1). Change 1 2-1541 VOLTAGE TEST Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. NOTE Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuits and cause severe burns or electrical shock. WARNING