TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 695 of 1632
TM 9-2320-366-20-2 Change 1 2-1503 CONTINUITY TEST Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. NOTE Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION (1) Remove personnel heater assembly for access (para 18-9). (2) Disconnect connector J912 from P912. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to connector P909 socket 5. (5) Connect negative (-) probe of multimeter to connector J912 socket 1 and note reading on multimeter. (6) If continuity is not present, repair wire 2006 from connector P909 socket 5 to connector J912 socket 1 (para 2-45) or replace auxiliary panel cable assembly (para 7-58). (7) If continuity is present, repair wire 2006 from connector P912 pin 1 to circuit breaker CB50 (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (8) Connect connector J912 to connector P912. (9) Install personnel heater (para 18-9). (10) Position auxiliary panel on auxiliary panel housing with six screws. (11) Tighten six screws to 24 lb-in (3N.m). (12) Connect batteries (para 7-57). (13) Lift dump body. (14) Place maintenance legs in stowed position. (15) Lower dump body. (16) Remove cargo sling from dump body lifting brackets. (17) Remove two dump body lifting brackets from from dump body. (18) Position two locking pins in dump body. (19) Install safety pins in two locking pins.