TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 689 of 1632
CONTINUITY TEST Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. NOTE Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION (1 Disconnect batteries (para 7-57). (2) Remove kick panel (para 16-3). (3) Disconnect connector P108 from connector J108. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to connector J108 pin 7. (6) Connect negative (-) probe of multimeter to connector P911 socket 1 and note reading on multimeter. (7) If continuity is not present, repair wire 2044 from connector J108 pin 7 to connector P911 socket 1 (para 2-45) or replace auxiliary panel cable assembly (para 7-58). (8) Connect connector P911 to DUMP BED UP/DOWN switch. (9) Position auxiliary panel on auxiliary panel housing with six screws. (10) Tighten six screws to 24 lb-in. (3N.m). TM 9-2320-366-20-2 Change 1 2-1502.1