KNOWN INFO TEST OPTIONS REASON FOR QUESTION NO 7. CAUTION Read CAUTION on following page. YES Continuity Test or STE/ICE-R Test #91 Repair wire 2044 from connector J108 pin 7 to connector P911 socket 1 (para 2-45) or replace auxiliary panel cable assembly (para 7-58). e144. M1090/M1094 DUMP BODY DOES NOT LOWER (CONT) POSSIBLE PROBLEMS Hydraulic oil level OK. PTO OK. Circuit breaker CB50 OK. Dashboard cable assembly OK. DUMP BED UP/DOWN switch OK. Is continuity present from connector J108 pin 7 to connector P911 socket 1? If continuity is not present, wire 2044 in auxiliary panel cable assembly is faulty. 2-1502 Change 2 Faulty auxiliary panel cable assembly. Faulty M1090/M1094 dump cable assembly. Faulty M1090/M1094 dump power cable assembly. TM 9-2320-366-20-2