TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 672 of 1632
KNOWN INFO TEST OPTIONS  NO  8.  CAUTION  Read CAUTION  on following page.  Continuity Test or  STE/ICE-R Test #91  YES  REASON FOR QUESTION  e143. M1090/M1094 DUMP BODY DOES NOT RAISE (CONT)  Repair wire 2043 from connector  P172 socket F to connector P108  socket 6 (para 2-45) or replace  M1090/M1094 dump power cable  assembly (para 7-125).  Repair wire 2043 from connector  J172 pin F to connector L8 socket 1  (para 2-45) or replace M1090/M1094  dump cable assembly (para 7-124).  2-1490.2 Change 2  TM 9-2320-366-20-2  POSSIBLE PROBLEMS  Faulty M1090/M1094 dump  cable assembly.  Faulty M1090/M1094 dump  power cable assembly.  Hydraulic oil level OK.  PTO OK.  Circuit breaker CB50 OK.  Dashboard cable  assembly OK.  DUMP BED UP/DOWN  switch OK.  Auxiliary panel cable  assembly OK.  Is continuity present from  connector P172 socket F to  connector P108 socket 6?  If continuity is not present,  wire 2043 in dump power  cable assembly is faulty, If  continuity is present, wire  2043 in dump cable assembly  is faulty.