TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 665 of 1632
CONTINUITY TEST Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. NOTE Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION (1) Disconnect connector P172 from connector J172. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to connector P172 socket H. (4) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (5) If continuity is not present, repair wire 3084 from connector P172 socket H to terminal lug TL77 (para 2-45) or replace M1090/M1094 dump power cable assembly (para 7-125). (6) If continuity is present, repair wire 3084 from connector J172 pin H to connector L8 socket 2 (para 2-45) or replace M1090/M1094 dump cable assembly (para 7-124). (7) Connect connector P172 to connector J172. (8) Connect connector L8 to solenoid valve. (9) Tighten screw in connector L8. (10) Lift dump body. (11) Place maintenance legs in stowed position. (12) Lower dump body. (13) Remove cargo sling from two dump body lifting brackets. (14) Remove two dump body lifting brackets from dump body. (15) Position two locking pins in dump body. (16) Install safety pin in two locking pins. TM 9-2320-366-20-2 Change 1 2-1485