KNOWN INFO  4.  TEST OPTIONS  REASON FOR QUESTION  CAUTION  Read CAUTION  on following page.  NO  YES  Continuity Test or  STE/ICE-R Test #91  e143. M1090/M1094 DUMP BODY DOES NOT RAISE (CONT)  Repair wire 3084 from connector  P172 socket H to terminal lug TL77  (para 2-45) or replace M1090/M1094  dump power cable assembly (para 7-125).  POSSIBLE PROBLEMS  TM 9-2320-366-20-2  Hydraulic oil level OK.  PTO OK.  Circuit breaker CB50 OK.  Auxiliary panel cable  assembly OK.  DUMP BED UP/DOWN  switch OK.  Dump body hydraulic  system OK.  Faulty M1090/M1094 dump  cable assembly.  Faulty M1090/M1094 dump  power cable assembly.  Repair wire 3084 from connector  J172 pin H to connector L8 socket 2  (para 2-45) or replace M1090/M1094  dump cable assembly (para 7-124).  If continuity is not present,  wire 3084 in M1090/M1094  dump power cable assembly  is faulty. If continuity is  present, wire 3084 in M1090/  M1094 dump cable assembly  is faulty.  Is continuity present from  connector P172 socket H  to a known good ground?  2-1484 Change 2