TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 664 of 1632
KNOWN INFO 4. TEST OPTIONS REASON FOR QUESTION CAUTION Read CAUTION on following page. NO YES Continuity Test or STE/ICE-R Test #91 e143. M1090/M1094 DUMP BODY DOES NOT RAISE (CONT) Repair wire 3084 from connector P172 socket H to terminal lug TL77 (para 2-45) or replace M1090/M1094 dump power cable assembly (para 7-125). POSSIBLE PROBLEMS TM 9-2320-366-20-2 Hydraulic oil level OK. PTO OK. Circuit breaker CB50 OK. Auxiliary panel cable assembly OK. DUMP BED UP/DOWN switch OK. Dump body hydraulic system OK. Faulty M1090/M1094 dump cable assembly. Faulty M1090/M1094 dump power cable assembly. Repair wire 3084 from connector J172 pin H to connector L8 socket 2 (para 2-45) or replace M1090/M1094 dump cable assembly (para 7-124). If continuity is not present, wire 3084 in M1090/M1094 dump power cable assembly is faulty. If continuity is present, wire 3084 in M1090/ M1094 dump cable assembly is faulty. Is continuity present from connector P172 socket H to a known good ground? 2-1484 Change 2