TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 649 of 1632
CONTINUITY TEST Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector L7 socket 2. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, go to step 7 of this fault. (5) If continuity is present, replace tailgate release solenoid (para 23-10). (6) Connect connector L7 to tailgate release solenoid. (7) Tighten screw in connector L7. TM 9-2320-366-20-2 Change 1 2-1471