TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 645 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1467 2-1467 2-1467 2-1467 2-1467 CONTINUITY TEST Underlift fold up Stinger in Underlift up Main winch LH in Main winch RH in Main winch RH out Main winch speed RH high Main winch LH out Main winch speed LH high Underlift down Stinger out Underlift fold down Function Emergency shutdown run Emergency shutdown kill Remote control box power TB Position 2 3 4 6 8 11 12 13 14 15 16 17 9 10 7 J1/J2 Pin g f e d b Y X W V U T S a Z c TABLE 2-17. REMOTE CONTROL BOX SWITCH CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to terminal block position listed in Table 2-17. Continuity Table. (3) Connect negative (-) probe of multimeter to J1/J2 pin listed in Table 2-17. Continuity Table and note reading on multimeter. (4) If continuity is not present, repair wire (para 2-45) or replace remote control wiring harness (para 7-117). (5) If continuity is present, perform Wrecker Pneumatic Troubleshooting (aa1. One Wrecker Function Does Not Operate From Wrecker Remote Control). (6) Install wrecker control panel top cover (para 17-20).