TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2  2-1463 2-1463 2-1463 2-1463 2-1463  CONTINUITY TEST  Underlift fold up  Stinger in  Underlift up  Main winch LH in  Main winch RH in  Main winch RH out  Main winch speed RH high  Main winch LH out  Main winch speed LH high  Underlift down  Stinger out  Underlift fold down  Emergency stop  UP  IN  UP  IN  IN  OUT  HIGH  OUT  HIGH  DOWN  OUT  DOWN  KILL  Function Remote Control Box Position  P2 Pin  Positive (+)  c  c  c  c  c  c  c  c  c  c  c  c  a  P2 Pin  Negative (-)  e  f  g  d  b  Y  X  W  V  U  T  S  Z  TABLE 2-15. REMOTE CONTROL BOX CONTINUITY TEST  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  pin listed in Table 2-15. Remote Control Box  Continuity Test.  (3) Connect negative (-) probe of multimeter to  pin listed in Table 2-15. Remote Control Box  Continuity Test.  (4) Position remote control box switch to position  listed in Table 2-15. Remote Control Box  Continuity Test and note reading on  multimeter.  (5) If continuity is not present, go to step 4 of this  fault.  (6) If continuity is present, repair wire (para 2-45)  or replace M1089 remote control wiring  harness (para 7-117).