TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1461 2-1461 2-1461 2-1461 2-1461 CONTINUITY TEST Function/Solenoid Terminal Board (+) Position Solenoid Resistance in Ohms Underlift fold up - L18 2 81-101 Stinger in - L13 Main winch speed LH high 3 4 6 8 11 12 13 14 15 16 17 81-101 81-101 81-101 81-101 81-101 81-101 81-101 81-101 81-101 Underlift up - L14 Main winch LH in - L6 Main winch RH in - L1 Main winch RH out - L2 Main winch speed RH high Main winch LH out - L5 Underlift down - L11 Stinger out - L16 Underlift fold down - L15 35-45 35-45 (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to terminal listed in Table 2-14. Actuator Solenoid Resistance Test. (3) Connect negative (-) probe of multimeter on terminal block TB-C and note reading on multimeter. (4) If resistance is less or greater than value listed in Table 2-14. Actuator Solenoid Resistance Test, notify DS Maintenance. (5) Install wrecker control panel top cover (para 17-20). TABLE 2-14. ACTUATOR SOLENOID RESISTANCE TEST