TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 636 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1458 2-1458 2-1458 2-1458 2-1458 START 1. NO YES KNOWN INFO TEST OPTIONS REASON FOR QUESTION INITIAL SETUP Equipment Conditions Top control panel cover removed (para 17-20). Personnel Required (2) WARNING Read WARNING on following page. POSSIBLE PROBLEMS Faulty actuator solenoids. Faulty wrecker remote control. Faulty remote control wiring harness. Is 24 vdc present at actuators controlled from remote unit? Voltage Test This question eliminates possible problems and determines where troubleshooting continues. Go to step 3 of this fault. Circuit breaker OK. Mode selector switch in NORMAL position. Hydraulic functions OK. Station selector switch in remote control position. All functions from wrecker control panel OK. Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Multimeter, Digital (Item 22, Appendix C) STE/ICE-R (Item 41, Appendix C) Materials/Parts Wire, Electrical, 50 ft (Item 67, Appendix D) References TM 9-4910-571-12&P e141. ONE WRECKER FUNCTION DOES NOT OPERATE FROM WRECKER REMOTE CONTROL