TM 9-2320-366-20-2 CONTINUITY TEST Change 1 2-1456.17 (1) Remove circuit breaker CB50 from PDP. (2) Remove electrical tape from conductor splice at pneumatic solenoid L17. (3) Cut wire 18 from conductor splice at pneumatic solenoid L17. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to terminal block TB18. (6) Connect negative (-) probe of multimeter to wire 18 and note reading on multimeter. (7) If continuity is not present, replace M1089 winch control wiring harness (para 7-142).