TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 61 of 1632

CONTINUITY TEST CONTINUITY TEST Change 2 2-958.9 TM 9-2320-366-20-2 (1) Disconnect connector P110 from CTIS ECU. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to connector P110 socket c. (4) Connect negative (-) probe of multimeter to connector P113 socket C and note reading on multimeter. (5) If continuity is not present, replace CTIS cable assembly (para 7-60). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P110 socket b. (3) Connect negative (-) probe of multimeter to connector P113 socket B and note reading on multimeter. (4) If continuity is not present, replace CTIS cable assembly (para 7-60).