TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 607 of 1632

Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. TM 9-2320-366-20-2 Change 1 2-1451 CONTINUITY TEST (1) Remove personnel heater for access (para 18-9). (2) Disconnect connector P912 from connector J912. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to connector J108 pin 16. (5) Connect negative (-) probe of multimeter to connector J912 pin/socket 1 and note reading on multimeter. (6) If continuity is not present, repair wire 2006 from connector J108 pin 16 to connector J912 socket 1 (para 2-45) or replace auxiliary panel cable assembly (para 7-58). (7) If continuity is present, repair wire 2006 from circuit breaker CB50 socket 2 to connector P912 pin 1 (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (8) Connect connector P912 to connector J912. (9) Install personnel heater (para 18-9). (10) Connect connector J108 to connector P108. (11) Install circuit breaker CB50 in PDP. (12) Install kick panel (para 16-3). (13) Install wrecker control panel top cover (para 14-4). (14) Connect batteries (para 7-57).