TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 603 of 1632
Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION NOTE CONTINUITY TEST Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. TM 9-2320-366-20-2 Change 1 2-1450.25 (1) Disconnect batteries (para 7-57). (2) Remove kick panel (para 16-3). (3) Disconnect connector J108 from connector P108. (4) Remove circuit breaker CB50 from PDP. (5) Set multimeter to ohms. (6) Connect positive (+) probe of multimeter to connector J108 pin 16. (7) Connect negative (-) probe of multimeter to circuit breaker CB50 socket 2 and note reading on multimeter. (8) If continuity is not present, go to step 17 of this fault.