TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 591 of 1632
CONTINUITY TEST TM 9-2320-366-20-2 Change 1 2-1450.13 (1) Remove power distribution panel (PDP) cover (para 16-2). (2) Remover circuit breaker CB50 from power distribution panel (PDP). (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to terminal block TBC(1). (5) Connect negative (-) probe of multimeter to to terminal block TBC(2) and note reading on multimeter. (6) Connect positive (+) probe of multimeter to terminal block TBC(2). (7) Connect negative (-) probe of multimeter to to terminal block TBC(3) and note reading on multimeter. (8) Connect positive (+) probe of multimeter to terminal block TBC(3). (9) Connect negative (-) probe of multimeter to to terminal block TBC(4) and note reading on multimeter. (10) Connect positive (+) probe of multimeter to terminal block TBC(4). (11) Connect negative (-) probe of multimeter to to terminal block TBC(5) and note reading on multimeter. (12) If continuity is not present between two terminal blocks noted above, replace jumper wire between terminal blocks that continuity is not present (para 7-33).