CONTINUITY TEST Change 1 2-1450.7 NOTE (1) Set multimeter to ohms. (2) Disconnect terminal lug on wire C from RH counter balance valve. (3) Connect positive (+) probe of multimeter to terminal lug on wire C. (4) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (5) If continuity is not present, go to step 14 of this fault. (6) If continuity is present, notify DS Maintenance. (7) Connect terminal lug on wire C to LH counter balance valve. Perform steps (8) through (11) if continuity is present from front/rear terminal lug of LH counter balance valve to ground. (8) Close LH and RH catwalks. (9) Install circuit breaker CB50 in PDP. (10) Install PDP cover (para 16-2). (11) Install wrecker control panel top cover (para 14-4). TM 9-2320-366-20-2