TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 579 of 1632

TM 9-2320-366-20-2 Change 1 2-1450.1 CONTINUITY TEST NOTE (1) Set multimeter to ohms. (2) Disconnect terminal lug on wire C from RH counter balance valve. (3) Connect positive (+) probe of multimeter to terminal lug on wire C. (4) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (5) If continuity is not present, go to step 8 of this fault. (6) If continuity is present, notify DS Maintenance. (7) Connect terminal lug on wire C to RH counter balance valve. Perform steps (8) through (11) if continuity is present from terminal lug on wire C to ground. (8) Close LH and RH catwalks. (9) Install circuit breaker CB50 in PDP. (10) Install PDP cover (para 16-2). (11) Install wrecker control panel top cover (para 14-4).